Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

COMTEKSCIENTIFICINSTRUMENTS 59f4646f9d192c0538502cb2 Products https://www.comtekscientific.in

Manufacturing test

Moderate speed 800-880 nm OCT spectrometer covering 2048 pixel USB3 camera operating at max line rate of 80 kHz.  Bandwidth tolerance of +/- 4 nm.  Imaging depth 4mm.  USB3 cable not included.
CS800-840/120-80-OC2K-U3
VIEW DETAILS
High speed 800-880 nm OCT spectrometer covering 2048 pixel USB3 camera operating at max line rate of 130 kHz.  Bandwidth tolerance of +/- 4 nm.  Imaging depth 4mm.  USB3 cable not included.
CS800-840/120-130-OC2K-U3
VIEW DETAILS
Based on our hyperspectral light fieldcamera technology, the ULTRIS SWIR 1 offersa versatile imaging solution with its broadwavelength range (980-1650 nm) within theShort-Wave Infrared region. The C-Mountcompatibility, supported by the integratedRelay Lens Adapter, enables seamlessintegration of various optics setups.
ULTRIS SWIR 1
VIEW DETAILS
WP X series low f-number Raman spectrometer with range and internal filter set optimized for 638 nm Raman measurements. Fully integrated system includes laser and probe, no external probe or fibers needed.   C = TEC Cooled (-15 deg C), 1k pixel S7031   ILP = Integrated 200 mW  laser and Raman probe   Integrated 25 um slit (default option)
WP-638X-F13-C-ILP
VIEW DETAILS
WP X series low f-number Raman spectrometer with range and internal filter set optimized for 785 nm Raman measurements. Fully integrated system includes laser and probe, no external probe or fibers needed.   F13 =  f/1.3   C = TEC Cooled (-15 deg C), 1k pixel S7031   ILP = Integrated 450 mW  laser and Raman probe   Integrated 25 um slit (default option)   OEM = exposed electronics, minimal housing, components mounted on baseplate designed to be built into a secondary enclosure
WP-785X-F13-C-ILP-OEM
VIEW DETAILS
WP X series low f-number Raman spectrometer with range and internal filter set optimized for 830 nm Raman measurements. Fully integrated system includes laser and probe, no external probe or fibers needed.   F13 =  f/1.3   R = TEC Regulated (+10 deg C), 2K pixel   ILP = Integrated 450 mW  laser and Raman probe   Integrated 25 um slit (default option)
WP-830X-F13-R-ILP
VIEW DETAILS
The ULTRIS X20 Plus, a dual-sensor iterationof the X20, is tailored for UAV-based aerialmapping. Accompanied by a second cameracapturing panchromatic images, it deliversa resolution of 1886 x 1886 pixels, ensuringhighly detailed imagery. This additional datafacilitates pansharpening, enhancing imagesand boosting the spatial resolution ofspectral data.
Supplier of ULTRIS X20 Plus
VIEW DETAILS
275nm LED Light Source Compact, energy-efficient light source with a narrow emission band. Available in a wide range of colors (wavelengths). Useful for illumination, machine vision, and specific wavelength applications
The Model 3800 MultiStim 8-Channel Programmable Stimulator is a multichannel programmable stimulator designed for a wide variety of applications. It is highly flexible, being capable of simultaneously delivering up to eight different series of pulse trains comprised of monophasic or biphasic pulses. In addition, the unit can produce trains of stepped pulses or paired pulses with easy to use built-in protocols.
Model 3800
VIEW DETAILS
The ER430 HV Sequencer is a system that provides four user programmable +/- 3 kV @100uA supplies. Each output can also be configured as voltage or current meters. Software is provided that controls the application of voltages in the sequence required to perform the experiment via an e-corder or independent USB connection.
The Model 3100 Intracellular Electrometer is a simple to use, low cost intracellular amplifier. Current compensation includes a dual-transient control that provides extremely precise adjustments to transient suppression during membrane recordings. The DC balance control eliminates the need for an external bridge or a differential input oscilloscope. The DC offset provides electrode offset control up to ±1V. An internal square-wave generator supplies a 100Hz current pulse to determine electrode resistance. Capacity compensation can adjust up to 35pF of electrode capacitance. Additional stray capacitance can be reduced by using the driven shield connector on the head stage probe
Model 3100
VIEW DETAILS
The Model 1700 Differential AC Amplifier has been designed for research or teaching applications which require extracellular neurophysiological recording from excitable tissue, such as nerve, muscle (EMG), EEG, EKG, and ERG recordings. The instrument contains four independent, isolated amplifiers in a single enclosure allowing the researcher to record several signals simultaneously. Combining four channels in one instrument significantly reduces equipment costs while providing a more convenient research environment.
Amplifier model 1700
VIEW DETAILS

Filter using tags

Stimulation InstrumentationRaman SpectrometersFluorescence SpectrometerPhotoluminescence Spectrometersolar SimulatorXenon light sourceDeuterium Tungsten Halogen Light sourceFiber optics SpectrometerElectrochemical WorkstationAmplifiersOCT Spectrometers#ramanspectrometer #raman #WasatchThinfilm Thickness measurement systemRefurbished Nanodrop SpectrophotometerND1000 repairrepair of Nanodrop SpectrophotometerNanodrop SpectrophotometerHyperspectral cameraSpectrometerlight source