Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

COMTEKSCIENTIFICINSTRUMENTS 59f4646f9d192c0538502cb2 service,Product https://www.comtekscientific.in

Manufacturing test

Broadband MRR 18-26 GHz spectrometer for molecularidentification and quantification, and undergraduateteaching and research.• The modular configuration enables compatibilitywith a variety of user-provided sample chambers andsources (consult BrightSpec for details).• Broadband and targeted measurement modes.• Excitation power 0.5 watts.• Includes BrightSpec sample chamber and vacuumsystem.• Includes laptop computer with BrightSpec EdgarTMsoftware for instrument control and spectral analysis.• Standard one-year warranty, including technicalsupport.• Technical support via phone, email, andteleconferencing.• Two days of installation and training included.
BrightSpec DiscoveryTM Modular Config
VIEW DETAILS
Responsive wavelength: from 180 to 1100 nm Optical resolution: 0.2 to 10.5 nm, depending on the combination of various slits and gratings.A variety of sensor can be chosen for specific application: EE2113: NIR Enhanced Back-Thinned 2048-pixel TEC linear sensor EE2063: UV Enhanced low noise type Back-Thinned 2048-pixel TEC linear sensor Modular configuration with various grating, sensor, and slit optionsIntegration times from 5 ms ~ 65 sec, depending on sensors16 bit, 15MHz A/D ConverterUSB 2.0 @ 480 Mbps (High speed)8-pin connector for interfacing to external6 user programmable digital I/O Plug-n-play interface for PC applicationExtremely precise continuous multiple exposures, providing up to 4,000 spectra buffering Flash ROM storage forWavelength Calibration CoefficientsLinearity Correction CoefficientsIntensity Calibration Coefficients
CCD Spectrometer EagleEye
VIEW DETAILS
The NS MiniTracer is the newest and most affordable member of the innovative line of NanoSpectralyzer instruments from Applied NanoFluorescence, LLC.Features:Most affordable fluorometer for near-infrared fluorophoresQuick measurements with user-friendly softwareTrace detection of sub-nanogram levels (SWCNTs); lowest LOD and LOQWide dynamic rangeRobust and compact design: footprint only 165 × 215 mm (6.5 × 8.5”)Near-infrared fluorescence spectra from 900 to 1600 nmOptional near-infrared absorption spectra from 900 to 1600 nmRapid sequence acquisition for kinetic studies or eluent monitoring638 nm excitation wavelength
Applied NanoFluorescence NS Mini Trace
VIEW DETAILS
Solar simulator with Band passes filters.Specifications:Light source: F1 condenser optics 100/240V, 50-60Hz(Including Housing, Power supply and Bulb)Bulb: OZONE Free lampBulb life :1000hrsColour temperature: 6000K (Daylight)High arc stabil Procurement of UV-Visible Spectrophotometer ityHigh colour rendering index; Ra>95Hot restart capabilityBulb Life: 1000 Hrs.Power  :150WSpectral range 200-2400nmBeam diameter: 50mmCompliance: standard complaint to AM1.5G operationOptical Power: Around 1500W/m2
WP X series low f-number Raman spectrometer with range and internal filter set optimized for 785 nm Raman measurements. Fully integrated system includes laser and probe, no external probe or fibers needed.   F13 =  f/1.3   C = TEC Cooled (-15 deg C), 1k pixel S7031   ILP = Integrated 450 mW  laser and Raman probe   Integrated 25 um slit (default option)   OEM = exposed electronics, minimal housing, components mounted on baseplate designed to be built into a secondary enclosure
WP-785X-F13-C-ILP-OEM
VIEW DETAILS
Xenon Light Source coupled Monochromatici) Light source: Xenon Lamp100 / 240 v, 50- 60 Hz.ii) Bulb: OZONE Free lampBulb life :1500hrsColor temperature: 6000K (Daylight)High arc stabilityHigh color rendering index; Ra>95Hot restart capabilityPower :100WBeam diameter: 50mm (Variable)Monochromator Specifications:i) Wavelength range: 240-800nmii) Wavelength resolution: 1 to 15nm depends on slitiii) Provision for selection of wavelengthsiv) Provision for changeable gratings to increase rangev) Inbuilt filters to cut off higher harmonics.
PL-100 features a highly versatile, cost effective and high-speed spectrometer with scan times of a few milliseconds to a few seconds.Fluorescence CCD array-based spectrometer with a wide excitation of 200nm to 850nm and an emission range of 250nm to 1000nm. The spectrometer can also be used for fluorescence measurements. Sample holders can house liquids, solids and thin films.
Supplier of PL-100
VIEW DETAILS
Solar simulator with Band passes filters.Specifications:Light source: F1 condenser optics 100/240V, 50-60Hz(Including Housing, Power supply and Bulb)Bulb: OZONE Free lampBulb life :1000hrsColour temperature: 6000K (Daylight)High arc stabil Procurement of UV-Visible Spectrophotometer ityHigh colour rendering index; Ra>95Hot restart capabilityBulb Life: 1000 Hrs.Power  :150WSpectral range 200-2400nmBeam diameter: 50mmCompliance: standard complaint to AM1.5G operationOptical Power: Around 1500W/m2
The NS MiniTracer is the newest and most affordable member of the innovative line of NanoSpectralyzer instruments from Applied NanoFluorescence, LLC.Features:Most affordable fluorometer for near-infrared fluorophoresQuick measurements with user-friendly softwareTrace detection of sub-nanogram levels (SWCNTs); lowest LOD and LOQWide dynamic rangeRobust and compact design: footprint only 165 × 215 mm (6.5 × 8.5”)Near-infrared fluorescence spectra from 900 to 1600 nmOptional near-infrared absorption spectra from 900 to 1600 nmRapid sequence acquisition for kinetic studies or eluent monitoring638 nm excitation wavelength
NS mini Tracer
VIEW DETAILS
DT-3000 combination of Deuterium-Tungsten-Halogen light source, with a single beam output of halogen through a see-thru deuterium electrode which provides continuous spectrum of 200nm to 2100nm. The DT-3000 is powered by Hamamatsu state of art, high power, high brightness, UV source which provides a very stable output and a long life.
DT-3000 UV Light Source
VIEW DETAILS
WP X series low f-number Raman spectrometer with range and internal filter set optimized for 532 nm Raman measurements. Laser and probe sold separately.   ## = 13 for f/1.3 or 18 for f/1.8   C = TEC Cooled (-15 deg C), 1k pixel S7031   Integrated 25 um slit and SMA connector (default option)
WP-532X-C-IC Raman Spectrometer
VIEW DETAILS
Computer Control Fluorescence  S pectrometer Specification.1. Wavelength range: 200 nm-900 nm Range or wider2.   Wavelength resolution: 1.34 nm/25μm slit3.   Detector: linear silicon CCD array4.   Integration time at 1ms – 60s5.   Signal-to-noise ratio (single scan):250:16.   Dynamic range: 1300:1 for a single acquisition7.   Computer Interface: USB 2.08.   A/D resolution:16 bit9.   User interchangeable slit without need for recalibration10.    Thermally stable optical bench11.    Light source: Osram XBO 100wattXenon lamp12.    Monochromatic light source directly coupled to CCD array detector13.    Sample compartment: Cuvette Holder for Liquids and45 holder for Solids, thin filmsand powders14.    Exciting optical filters: Excitation through monochromator Continuous variation ofWavelength from 240- 850nm15.    Emission monochromator: Czerny turner diffraction grating with CCD solid statearray detector capable of simultaneous acquisition of all emission wavelengths16.    Excitation wavelength :240-850nm17.    Emission wavelength: 200- 900nm18.    Emission Bandwidth: 1nm19.    Upgrade: Abs, fluor, trans, Refl, color.20.    Attachment: Microscope21. Power: 220 to 250V 5022. Fluorescence display value: 0 to Over6500023.  Graphical interface software with schematic feature to drag and paste hardware and software–math functions.24.  The software should also have the following features: independent storage and retrieval of dark, reference sample and processed spectra; opening the spectrum and the data in the Excel format; Overlay spectra; viewing spectra in either graphical or tabular form; The software should have the facility to produce different orders of derivative spectra with high resolution both online and offline.
Fluorescence Spectrometer FL100-CC
VIEW DETAILS

Filter using tags

Stimulation InstrumentationRaman SpectrometersFluorescence SpectrometerPhotoluminescence Spectrometersolar SimulatorXenon light sourceDeuterium Tungsten Halogen Light sourceFiber optics SpectrometerElectrochemical WorkstationAmplifiersOCT Spectrometers#ramanspectrometer #raman #WasatchThinfilm Thickness measurement systemRefurbished Nanodrop SpectrophotometerND1000 repairrepair of Nanodrop SpectrophotometerNanodrop SpectrophotometerHyperspectral cameraSpectrometerlight source

Have any question or need any business consultation?

Have any question or need any business consultation?

Contact Us